- #01Plan and document coordination
Obvious clerical, title-block, sheet-index, permit-description, or cross-sheet inconsistencies visible in the submitted documents. A Courtesy Comment on these items does not cause FCC to fail or return the plan set unless the same condition also creates a building-code compliance issue within FCC's review scope.
FBC-B 107.2.1 - #02Zoning and site coordination
Apparent setback, lot-coverage, use, or site-dimension conflicts visible in the submitted plans that could cause the plans to fail Planning and Zoning review. Planning and Zoning makes the zoning and lot-compliance determination. The absence of a Courtesy Comment is not approval of those separate requirements.
- #03Floodplain coordination
Apparent inconsistencies or missing coordination in flood-zone, design-flood-elevation, finished-floor, or flood-opening information shown on the plans that could cause the plans to fail floodplain review. The floodplain administrator makes the determination. The absence of a Courtesy Comment is not approval of those separate requirements.
- #04Fire-authority coordination
Apparent separately reviewed fire alarm, sprinkler, hood-suppression, smoke-control, or similar coordination issues visible on the plans that could cause the plans to fail fire review. The fire marshal makes the determination. The absence of a Courtesy Comment is not approval of those separate requirements.
Commercial Concrete Footing/Foundation/Wall
Concrete slab, footing, foundation, or freestanding nonretaining CMU or concrete wall at commercial or multifamily property.
Last updated: Sep 29, 2026
Section 1
Required Documents
Submit these with your initial project package.
Always required
- Construction PlansConstruction plans showing concrete work layout, dimensions, and reinforcement. Plans prepared by a Florida-registered architect or engineer carry that professional's seal. Plans prepared by a contractor or owner are accepted without a seal unless Florida law or the building department requires professional plans.
- Site Plan / SurveySite plan or survey showing property boundaries and concrete work footprint
Courtesy screen
Courtesy screen on every plan review
Every plan FCC reviews receives a limited courtesy screen for the items below when they are reasonably visible in the submitted documents. If we see an apparent issue that could cause the plans to fail review by another agency, we will identify it as a Courtesy Comment. Courtesy Comments alone do not cause FCC to fail or return the plan set unless the same condition also creates a building-code compliance issue within FCC's review scope. The responsible agency makes the final determination—for example, Planning and Zoning for setbacks, lot coverage, use, and other lot-compliance matters. The absence of a Courtesy Comment is not approval of those separate requirements.
Section 2
Approval criteria for this project type
These are the building-code criteria FCC uses to determine the plan-review result. An unresolved item may be issued as a Required Correction and cause the plan set to be returned for correction.
BuildingRequired
- #01Design wind speed & exposureLife Safety
Structural drawings must declare design wind speed (Vult) and exposure category matching the jurisdiction's wind speed map.
FBC-B 1609ASCE 7-22 - #02Footing / foundation designLife Safety
Footing or foundation design must show dimensions, reinforcement, depth, and connection to the structure above.
FBC-B 1809 - #03Occupancy classificationLife Safety
Occupancy group must be clearly stated. Any change of occupancy requires FBC-EB 1001 compliance path.
FBC-B 302FBC-EB 1001 - #04Engineer of record seal, when engineeredDocumentation
When a Florida engineer prepared the structural drawings, the document carries that engineer's seal and signature. Contractor- or owner-prepared structural drawings need a seal only when Florida law or the building department requires one.
Florida Statutes Chapter 471FBC-B 107.3.5
Section 3
Inspection Walkthrough
Inspections are listed in their typical phase order. Your own inspection list comes from your approved plans. Inspections marked “If in scope” apply only when your plans include that work. Call (772) 222-6679 with questions.
Building
Footing / Grade Beam
If in scope- Footing dimensionsCritical
Verify footing width and depth match approved plans
- Rebar size and spacingCritical
Verify rebar size, spacing, and placement per plans
- UFER grounding electrodeCritical
Where the approved electrical design uses a concrete-encased electrode, show the specified material, length, placement, and connection before concrete.
NEC 250.52 - Foundation anchorage layout
Verify anchor bolt placement for sill plate attachment
Stem Wall
If in scope- Stem wall layoutCritical
Match the wall location and dimensions to the approved foundation plan.
- Wall reinforcementCritical
Check vertical and horizontal reinforcement, laps, and clear cover before fill.
- Anchorage and connectionsCritical
Show anchors and connections between the stem wall, footing, and floor system.
- Open cells and formsCritical
Keep masonry cells or forms open and visible until inspection.
- Backfill holdCritical
Do not backfill or conceal the stem wall before the inspection.
Slab
If in scope- Slab vapor barrierCritical
Verify vapor barrier is installed under slab per plans
- Slab thickness and wire meshCritical
Verify slab thickness and reinforcement per plans
- Slab forms and elevationCritical
Verify slab outline, thickness, and elevations match the approved plans.
- Under-slab preparationCritical
Show prepared base, penetrations, and required under-slab work before the pour.
- Reinforcing supportCritical
Show slab steel or mesh supported at the planned position and with required laps.
Fill Cell / Column
If in scope- Vertical rebar placementCritical
Verify vertical rebar is properly placed and spaced in block wall
- Pre-grout cell inspectionCritical
Show open cells, cleanouts, bars, laps, and cover before grout placement.
- Open vertical cellsCritical
Keep reinforced masonry cells visible before grout is placed.
- Column reinforcementCritical
Verify column or pilaster steel, ties, laps, and cover against the plans.
- Cell cleanlinessCritical
Confirm reinforced cells are clear of mortar droppings and debris.
Lintel / Tie Beam
If in scope- Tie beam reinforcementCritical
Verify tie beam rebar size, spacing, and lap splices per plans
- Lintel reinforcementCritical
Verify lintel rebar and sizing over openings per plans
- Beam forms and bearingCritical
Check tie beam and lintel forms, bearing, and dimensions against the plans.
- Concrete placement holdCritical
Leave beam and lintel reinforcement visible until inspection.
Building Final
Typical Final- Completed structural scopeCritical
Confirm slab, foundation, or freestanding wall matches approved dimensions and details.
FBC-B 110.3 - Visible safety and finishCritical
Show wall stability, exposed edges, and finished site conditions for this permit.