- #01Plan and document coordination
Obvious clerical, title-block, sheet-index, permit-description, or cross-sheet inconsistencies visible in the submitted documents. A Courtesy Comment on these items does not cause FCC to fail or return the plan set unless the same condition also creates a building-code compliance issue within FCC's review scope.
FBC-B 107.2.1 - #02Zoning and site coordination
Apparent setback, lot-coverage, use, or site-dimension conflicts visible in the submitted plans that could cause the plans to fail Planning and Zoning review. Planning and Zoning makes the zoning and lot-compliance determination. The absence of a Courtesy Comment is not approval of those separate requirements.
- #03Floodplain coordination
Apparent inconsistencies or missing coordination in flood-zone, design-flood-elevation, finished-floor, or flood-opening information shown on the plans that could cause the plans to fail floodplain review. The floodplain administrator makes the determination. The absence of a Courtesy Comment is not approval of those separate requirements.
- #04Fire-authority coordination
Apparent separately reviewed fire alarm, sprinkler, hood-suppression, smoke-control, or similar coordination issues visible on the plans that could cause the plans to fail fire review. The fire marshal makes the determination. The absence of a Courtesy Comment is not approval of those separate requirements.
Single Family Framed Deck/Dock
Build a framed exterior deck or dock. Select footings, piles, and waterproofing from the approved design.
Last updated: Sep 29, 2026
Section 1
Required Documents
Submit these with your initial project package.
Always required
- Construction PlansConstruction drawings showing deck layout, framing, and connection details. Plans prepared by a Florida-registered architect or engineer carry that professional's seal. Plans prepared by a contractor or owner are accepted without a seal unless Florida law or the building department requires professional plans.
- Site Plan / SurveySite plan or survey showing property boundaries, setbacks, and deck footprint
Courtesy screen
Courtesy screen on every plan review
Every plan FCC reviews receives a limited courtesy screen for the items below when they are reasonably visible in the submitted documents. If we see an apparent issue that could cause the plans to fail review by another agency, we will identify it as a Courtesy Comment. Courtesy Comments alone do not cause FCC to fail or return the plan set unless the same condition also creates a building-code compliance issue within FCC's review scope. The responsible agency makes the final determination—for example, Planning and Zoning for setbacks, lot coverage, use, and other lot-compliance matters. The absence of a Courtesy Comment is not approval of those separate requirements.
Section 2
Approval criteria for this project type
These are the building-code criteria FCC uses to determine the plan-review result. An unresolved item may be issued as a Required Correction and cause the plan set to be returned for correction.
BuildingConditional review scope
- #01Design wind speed & exposureLife Safety
Structural drawings must declare design wind speed (Vult) and exposure category matching the jurisdiction's wind speed map.
FBC-R R301.2.1ASCE 7-22 - #02Footing / foundation designLife Safety
Footing or foundation design must show dimensions, reinforcement, depth, and connection to the structure above.
FBC-R R403FBC-B 1809 - #03Attachment to existing structureLife Safety
Connection details between the new work and the existing structure must show fastener type, spacing, and embedment.
FBC-R R301.1 - #04Plan review applicability (FBC 107.3.5 minimum criteria)Documentation
Standalone framed deck/dock scope is not in FBC-B 107.3.5 minimum criteria for 1&2 family. FCC performs this review only when the building department requires plan review or the client opts in.
FBC-B 107.3.5 - #05Engineer of record seal, when engineeredDocumentation
When a Florida engineer prepared the structural drawings, the document carries that engineer's seal and signature. Contractor- or owner-prepared structural drawings need a seal only when Florida law or the building department requires one.
Florida Statutes Chapter 471FBC-B 107.3.5
Items marked Conditional review scope are non-blocking. Per FBC 107.3.5, plan review isn't required for these scopes — FCC reviews them when the building department requests it or the client wants the extra set of eyes.
Section 3
Inspection Walkthrough
Inspections are listed in their typical phase order. Your own inspection list comes from your approved plans. Inspections marked “If in scope” apply only when your plans include that work. Call (772) 222-6679 with questions.
Building
Footing / Grade Beam
If in scopeBD-DependentMost jurisdictions skip this inspection for this project type. Confirm with your building department whether they'll require it.
- Footing dimensionsCritical
Verify footing width and depth match approved plans
- Rebar size and spacingCritical
Verify rebar size, spacing, and placement per plans
- UFER grounding electrodeCritical
If this footing contains a concrete-encased electrode, show its length and connection before concrete.
NEC 250.52 - Foundation anchorage layout
Verify anchor bolt placement for sill plate attachment
- Forms and footing locationCritical
Verify footing and grade beam forms match the approved foundation plan before the pour.
- Excavation conditionCritical
Check that the excavation is clean, stable, and ready for concrete.
Piling / Pile Cap
If in scopeBD-DependentMost jurisdictions skip this inspection for this project type. Confirm with your building department whether they'll require it.
- Pile layoutCritical
Match pile or pier locations and count to the approved structural plan.
- Pile size and depthCritical
Document pile dimensions, embedment, or installation records required by the plans.
- Pile cap reinforcementCritical
Show cap or pier forms, steel, laps, and cover before concrete.
- Connection to structureCritical
Show specified pile-to-cap and cap-to-structure connections.
- Engineering documentationCritical
Have the approved pile design and required installation or test records available.
Framing
- Wall stud spacing and sizeCritical
Verify stud size and spacing match approved plans
FBC-R R602.3 - Headers and beamsCritical
Verify header and beam sizes over openings per plans
FBC-B 110.3 - Top and bottom plate connectionsCritical
Verify plate configuration, laps and anchorage against the approved framing design; do not assume double top plates.
FBC-B 110.3 - Corner and intersection bracingCritical
Verify proper bracing at corners and wall intersections
FBC-B 110.3 - Window and door rough openingsCritical
Verify rough openings match approved plans for size and location
FBC-B 110.3 - Hurricane straps and hold-downsCritical
Compare roof-to-wall connectors and straps with the approved high-wind design and connector schedule.
FBC-R R301.2.1.1 - Fire blockingCritical
Verify fire blocking is installed at required locations
FBC-R R302.11
Balcony / Walking Surface Waterproofing
If in scopeBD-DependentMost jurisdictions skip this inspection for this project type. Confirm with your building department whether they'll require it.
- Substrate preparationCritical
Show a clean, sound balcony deck before waterproofing is concealed.
- Membrane continuityCritical
Show the waterproof barrier across the walking surface and up adjacent walls.
- Flashing and transitionsCritical
Show waterproofing at doors, edges, drains, and penetrations.
- Slope and drainageCritical
Confirm the surface drains as shown on the approved plans.
- Product installationCritical
Have product and approved installation details available.
Building Final
Typical Final- Walking surfaceCritical
Show deck or dock, stairs, and edges.
FBC-B 110.3 - Supports and connectionsCritical
Show accessible footings or piles and frame connections.
FBC-B 110.3 - Stairs, handrails and landings when providedCritical
Where stairs exist, measure risers, treads, handrails and top/bottom landings.
FBC-R R311.7FBC-R R311.7.5FBC-R R311.7.6FBC-R R311.7.8 - Guards where requiredCritical
Show guard location and measure height at open sides where required.
FBC-R R312.1.1FBC-R R312.1.2