Hurricane shutter installs are seasonal — which means the permit window is tight, and a missed inspection can push a homeowner into the next storm unprotected. Freedom Code Compliance (FCC) performs virtual inspections for manual and motorized hurricane shutter installations under Florida Statute 553.791, verifying Florida Product Approval (FPA) or Miami-Dade NOA numbers, anchor spacing, and substrate attachment. Motorized systems add an electrical component that may require plan review.
Plan Review Report
Seabreeze Shutters · Single Family Manual Hurricane Screen/Shutters
Project
- Address
- 1530 NE Seabreeze Ln, Jensen Beach, FL
- Building department
- Martin County
- Permit
- BR-26-005088
Design criteria
On the plans
Checked against
- Building code
- Plans: FBC 8th Edition (2023)
- Checked: Edition in effect
- Wind speed (Vult)
- Plans: 165 mph
- Checked: 163 mph at this site, Risk Category II
- Risk category
- Plans: II
- Checked: Residential occupancy
- Flood zone
- Plans: Zone X
- Checked: FEMA Zone X, minimal flood hazard
Documents and seals
Address and scope on every sheet match the project.
What we verified
- Florida product approvalF.S. 553.842
- Wind-borne debris protectionFBC-R R301.2.1.2
- Attachment to the existing structureFBC-R R301.1
Courtesy comments
None on this plan set.
We solve your biggest challenges
- Pre-season backlogs at the building department when every homeowner wants shutters installed before June
- Inspectors flagging anchor embedment or spacing that was never clarified in plan review
- NOA / FPA product-approval mismatches discovered at the final instead of before install
- Motorized shutter electrical tie-ins bouncing between electrical and building finals
Hurricane Shutter Contractors
Built-in speed tools for every permit
Fast Code Review Workflows
Keep permit packages moving with plan review workflows designed for speed, consistency, and clear correction cycles.
AI-Assisted Plan Reviews
FCC uses software-assisted checks on single-trade plan reviews, with plans examiners completing each review.
Virtual Inspections On Demand
Request virtual inspections whenever your crew is ready and keep projects moving without waiting on site visits.
Every project in one place
Submit plans, request inspections and track every project in myFCC, on your phone or desktop.
Check Out myFCCProjects
Common hurricane shutter contractors projects
We have experience with thousands of hurricane shutter contractors projects across Florida.
- Manual Accordion Shutters
- Roll-Down Hurricane Shutters (Manual and Motorized)
- Removable Storm Panels
- Bahama Shutters
- Colonial Shutters
- Motorized Roll-Down Systems with Electrical Interconnect
Single-trade plan review
Minutes
Single-trade plan reviews typically come back in minutes. Single-family projects take hours and commercial projects 1–2 days. Live and offline inspection results come back in minutes too.
Apply nowMeasured on our platform7-day average · Oct 10 – Oct 16
- Request to live inspector
- Offline request to result
- Plan review in workable business hours, start to approved plans
- Workable time is the time our team can act on your plans during business hours (weekdays 9–5, Fridays 9–4 ET). It’s how long a compliant submission with no blockers takes us to review and approve within business hours. Time waiting on you, like corrections or a quote out for approval, isn’t counted.
No scheduling required. You simply request the inspection when the work is ready. Live inspection requests are taken Monday to Friday, 9 am to 4:30 pm ET; offline inspections can be submitted any time.
FAQ
Hurricane Shutter Contractors FAQs
Do hurricane shutter permits need plan review with FCC?
Manual shutter installs (accordion, storm panel, Bahama, colonial) in Florida are typically inspection-only — Freedom Code Compliance verifies the Florida Product Approval or Miami-Dade NOA and anchor details at the virtual final. Motorized roll-down systems usually add an electrical component (low-voltage control or 120V hardwired motor) that may trigger plan review depending on the jurisdiction. FCC handles the plan review when required and the inspection in both cases. FCC does not pull permits or file the NTBO.
How does FCC verify NOA and product approval on hurricane shutters?
At the virtual final, Freedom Code Compliance cross-checks the shutter system's Florida Product Approval (FPA) number or Miami-Dade Notice of Acceptance (NOA) against the approved wind-zone rating for the project location. FCC verifies the product on site matches the approved system — same manufacturer, same configuration, same anchor schedule — and that the installed anchor spacing, embedment depth, and substrate type (concrete, CMU, wood framing, stucco-over-frame) are consistent with that approval. Mismatches get flagged with specific, actionable correction items through the myFCC app.
How fast are hurricane shutter inspection results?
Live video inspections through myFCC Mobile return results before the call ends — contractors are matched with a licensed inspector in minutes, walk the install on camera, and leave the site with a result. Offline inspections with GPS-tagged photos of anchor spacing, product labels, and attachment points are typically reviewed and returned within minutes during normal business hours. For motorized shutters that require plan review, that is a separate single-trade review, typically back in minutes, tracked independently from the inspection clock.